Build Pigway Frame Flow with bilingual UI, complete KoKonna driver and safe automation

This commit is contained in:
Pigway
2026-10-02 00:03:48 +08:00
commit 6652590b84
79 changed files with 13773 additions and 0 deletions
+27
View File
@@ -0,0 +1,27 @@
# Real device test plan / 单次实机测试计划
**Not executed. Explicit owner authorization is required before any write.**
只读核对完成后询问:“真实设备只读验收完成,是否允许进行一次真实图片上传与显示测试?”
1. GET Frame Flow device (driver POST /device); record current imageId AND coverId,
synced, geometry, model, rotation, timezone, firmware, heartbeat and battery.
2. POST /listImages for metadata only. Record count, current image, sorted IDs,
duplicates, name/date/dimensions anomalies. No download-all action.
3. Stop on discrepancy. Missing model fields must be reported as unavailable.
4. Once explicitly authorized, locally render **one** 1200×1600 test image containing
PIGWAY FRAME FLOW TEST and Shanghai timestamp, no private content.
5. Record an operation ID and previous image; one upload only, no write retries.
6. Poll device read-only no more often than 60 seconds, respecting the 20/min budget.
Confirm imageId and synced. If sent but response lost, mark UNKNOWN, block writes,
reconcile gallery/device; never upload again to guess the outcome.
7. Keep the test image visible at most 1–3 minutes, then restore the recorded artwork
with a separate tracked switch operation. Query once more to confirm restored
imageId and synced. Record coverId after restoration too.
8. Delete only that known test image after restoration is positively confirmed AND
it is not a base/previous/override/current reference. If ambiguous, leave it and
report. Never delete art or retry a timed-out delete.
9. Disable real writes again. Report each operation ID/result and remaining test image.
The API cannot set coverId. Restoration guarantees a requested image switch when
confirmed, not arbitrary cover metadata restoration. Physical screen refresh has
no documented pixel telemetry; visual owner observation supplements cloud synced.